The German Geothermal Congress 2026
20 - 22 October 2026 | Potsdam, Germany
Conference Agenda
Overview and details of the sessions of this conference. Please select a date or location to show only sessions on that day or at that location. Please select a single session for detailed view (with abstracts and downloads if available).
|
Daily Overview |
| Session | |||
F22: Shallow Geothermal
| |||
|
Language:
| |||
| Presentations | |||
2:00pm - 2:20pm
ID: 219 / F22: Shallow Geothermal: 1 Topics: 1.09 Surface facilities, large-scale or high-temperature heat pumps Don’t Overlook the Heat Exchanger Station: Maximising Geothermal Heat Extraction at the Surface Alfa Laval Geothermal energy plants require significant investment to extract heat from the ground, making it critical to verify, already at the design stage, that surface heat recovery is maximised. This demands heat exchangers optimised for heat transfer performance, mechanical robustness. Heat extraction is limited by the production well flow rate and a large ΔT is required to provide maximum capacity. Best practices from successful installations across Europe confirm that every well is unique, and the water properties determine appropriate plate and gasket material as well as the fouling and scaling potential. To minimise fouling risk, heat exchangers should be designed for high channel turbulence, reducing cleaning frequency and maintenance needs. High turbulence generates effective shear stress on the plate surface, ensuring optimal heat transfer — but it comes at the cost of a higher pressure drop across the unit. A close temperature pinch introduces thermodynamic challenges, increasing the required surface area, which in turn limits channel turbulence and the achievable shear stress and pressure drop. This creates a fundamental design trade-off between maximising heat extraction and maintaining sufficient shear stress to keep surfaces clean. Gasketed plate heat exchangers allow for a pinch between the primary outlet and the secondary inlet down to 1 °K compared to 4-5 °K with shell and tube solutions. In conclusion, deliberate heat exchanger selection, combining optimised operating conditions with suitable materials, reduces lifecycle operating costs, increases energy output, and ultimately enhances the return on investment.
2:20pm - 2:40pm
ID: 235 / F22: Shallow Geothermal: 2 Topics: 2.05 District-scale solutions, operational planning and optimisation An open-data GIS tool for lot-level planning of shallow geothermal potential in urban areas 1: Christian-Albrechts-Universität zu Kiel, Germany; 2: Deutsches Zentrum für Luft- und Raumfahrt, Institut für Vernetzte Energiesysteme, 26129 Oldenburg, Germany; 3: IREES GmbH, Durlacher Allee 77, 76131 Karlsruhe, Germany Urban heating is still difficult to decarbonize, especially in dense residential areas where space for borehole heat exchangers (BHEs) is limited. This work presents an open-data GIS tool for estimating shallow geothermal potential at lot level and for supporting early planning of ground source heat pump systems. The tool is implemented in QGIS and Python to work with public or standard geospatial data, such as lots, building footprints, roads, land use restrictions, and geological data. First, the available installation space is calculated by removing buffer zones around buildings, lot boundaries, trees, roads, water areas, and other exclusion zones. Then, BHE positions are placed using a rotated and shifted hexagonal grid. For each BHE, the annual extractable heat is estimated from subsurface thermal conductivity based on VDI guideline tables. The results are then compared with residential heat demand at lot level. Besides the maximum technical potential, the tool can also identify the minimum number of BHEs needed to cover the demand of each lot. The tool was tested in the Donnerschwee district of Oldenburg, Germany. In the base case, 1082 lots have residential heat demand, of which 911 provide space for at least one BHE. The results show that BHEs can cover about 34.7 GWh/a, or 61.1% of the district heat demand. About 36.2% of the lots can be fully supplied. Scenario analysis shows that borehole depth, BHE spacing, and distance to neighboring lots are the most important parameters for maximizing the geothermal potential. 2:40pm - 3:00pm
ID: 142 / F22: Shallow Geothermal: 3 Topics: 2.08 Numerical design of shallow geothermal systems, modelling, simulation, AI Thermal Interference Between Shallow Geothermal Borefields: A Comparison of Analytical Methods 1: Enead BV, Retie, Belgium; 2: Polytechnique Montréal, Département de génie mécanique, Montréal, Québec, Canada As shallow geothermal systems become increasingly common in urban environments, the thermal interference between neighboring borefields is no longer negligible. Current geothermal design tools typically assume an infinite, unaffected ground domain beyond a single borefield, an assumption that breaks down in regions with multiple geothermal systems (like in The Netherlands). This paper presents and compares three analytical methods of increasing complexity for quantifying the normalized thermal interference between neighboring borefields. The first method applies the infinite line source (ILS) solution with superposition over all emitting boreholes in the source borefield to all affected boreholes in the target borefield. The second method employs the finite line source (FLS) solution with the same superposition strategy, but assumes a uniform heat transfer rate (UHTR) along each borehole. The third method first solves the emitting borefield under the more representative uniform borehole wall temperature (UBWT) condition to obtain the heat extraction rate per discretized borehole segment, then uses these spatially varying heat extraction rates to compute the resulting temperature change in the affected borefield.
3:00pm - 3:20pm
ID: 353 / F22: Shallow Geothermal: 4 Topics: 2.03 Reuse of mining infrastructure Photogrammetric evaluation of surface level changes at a mine thermal energy storage site in the Ruhr area 1: Fraunhofer IEG, Deutschland; 2: Ruhr-Universität Bochum To advance the energy transition and the associated shift toward renewable energy, adjustments to decarbonize heat production and developing ways of storing heat are essential. A relatively new way of producing and storing heat is the so called mine thermal energy storage (MTES). Old, flooded mining cavities provide the necessary storage volumina and low-permeable host rock formations to store large quantities of heat in the subsurface that could otherwise not be built in a cost-effective manner. To investigate the challenges and opportunities of seasonal heat storage in abandoned coal mines, the WINZER project developed a unique MTES system using an abandoned near-surface colliery in Bochum, Germany. The mine was tapped by three boreholes allowing the lifting and reinjecting of heated minewater using solar power. To address concerns regarding the formation of sinkholes at this shallow MTES site, a comprehensive monitoring campaign using photogrammetric evaluation of surface level heights using drone flights was conducted since the inception of the testing site in 2021. Despite the system being operational for multiple years, as well as several high-volume and high-temperature tests being conducted, no significant changes regarding the surface level have been observed. We present the results of this monitoring campaign as well as its implications for shallow mine thermal energy storage systems.
3:20pm - 3:40pm
ID: 192 / F22: Shallow Geothermal: 5 Topics: 1.05 Numerical modelling, simulation, THMC, AI Investigation of the geothermal performance of a horizontally deviated borehole heat exchanger 1: Christian-Albrechts-Universität Kiel, Deutschland; 2: Green Therma, Dänemark; 3: Stadtwerke Flensburg GmbH, Deutschland; 4: GEOimpulse GmbH, Deutschland The widespread occurrence of extensive salt structures in Northern Germany limits hydrothermal energy utilization significantly. However, closed loop deep borehole heat exchangers (BHEs) represent a technology for the extraction of geothermal heat in the scale of 100s of kW. To enhance the thermal performance of a deep BHE even further, the vertical borehole layout can be extended using a deviated borehole with a long horizontal section. This work therefore quantifies the achievable increase of thermal performance using numerical simulations by quantifying the influence of the borehole layout on return temperature, thermal power and subsurface temperature distribution for a deep coaxial BHE with varying extended horizontal section. Results are compared to the case of a vertical BHE. The parametrization is defined using typical parameters for a deep BHE and assuming a vacuum-insulated inner pipe. The geological setting corresponds to a typical sedimentary layered structure. Simulation results show that compared to a vertical BHE with a total length of 3000 m, a deviated BHE reaching the same depth but including a horizontal section of equal length increases thermal power from 313 kW to 792 kW by about 153% as well as return temperatures in Kelvin by 4.0% under the same geological and operational conditions. Using a shorter horizontal section of 1500 m, the thermal power and return temperatures increase by 69% to 528 kW and by 1.8%, respectively. These simulations thus demonstrate the large geothermal potential of these novel deviated deep borehole heat exchangers. | |||