The German Geothermal Congress 2026
20 - 22 October 2026 | Potsdam, Germany
Conference Agenda
Overview and details of the sessions of this conference. Please select a date or location to show only sessions on that day or at that location. Please select a single session for detailed view (with abstracts and downloads if available).
|
Daily Overview |
| Session | |
|
F26: Heat Storage
Location: Room 0.214 Session Chair: Thomas Gruner, SLB Cambridge Research | |
| Presentation 5 | |
5:30pm - 5:50pm
ID: 155 / F26: Heat storage EN: 5 Topics: 3.02 Closed Storage Systems, BTES Cost-effectiveness of coaxial medium-deep borehole thermal energy storages for various waste heat sources and district heating temperatures 1: HAWK Hildesheim/Holzminden/Göttingen University of Applied Sciences and Arts, Faculty of Resource Management, Rudolf-Diesel-Straße 12, 37075, Göttingen, Germany; 2: EURAC Research, Institute for Renewable Energy, Viale Druso 1, 39100, Bolzano, Italy Temporal mismatches between waste heat (WH) availability and heat demand limit WH utilization and require thermal energy storage. Medium-deep borehole thermal energy storages (MDBTES) have recently gained attention. However, previous studies mainly focused on solar thermal integration, while the effects of different WH source temperatures and district heating (DH) supply temperatures on MDBTES performance and economics remain understudied. This study assesses the cost-effectiveness of coaxial MDBTES with depths of 400–1000 m and field sizes of 4–64 boreholes for WH source temperatures of 30, 50, 70, and 90 °C and DH design supply temperatures of 120 and 70 °C. A scenario without WH injection is included for comparison. Simulations are performed using a Python-based framework coupling subsurface thermal processes, heat pump operation, and economic assessment. The results show break-even specific MDBTES costs ranging from 165 to 550 €/m. MDBTES becomes most attractive when high-temperature WH is stored for use in low-temperature DH networks, whereas storing high-temperature WH at greater depths is less beneficial. Across all cases, lifetime mean specific heat injection and extraction rates range from 20 to 152 W/m and 18 to 65 W/m, respectively. WH injection during non-heating periods significantly increases heat extraction compared with cases without injection. Sensitivity analysis identifies ground thermal conductivity and system lifetime as the most influential parameters for economic feasibility, while ground density and specific heat capacity have only minor effects. Overall, technological advancements and reductions in drilling costs are essential prerequisites for the widespread, cost-effective deployment of MDBTES for WH management. | |
