The German Geothermal Congress 2026
20 - 22 October 2026 | Potsdam, Germany
Conference Agenda
Overview and details of the sessions of this conference. Please select a date or location to show only sessions on that day or at that location. Please select a single session for detailed view (with abstracts and downloads if available).
|
Daily Overview |
| Session | ||
|
Poster Exhibition
Location: Kongress-Saal All posters will be displayed on both conference days. You can put up your poster from 1.10 pm. | ||
| Presentation 19 | ||
ID: 123
/ Poster Number: 19
Topics: 1.03 Development including drilling technology, hydraulic testing, stimulation Engineering the Entry Point: A Next‑Generation GeoESP® Intake for Geothermal ESPs Halliburton, United States of America High-capacity geothermal wells impose demanding conditions on artificial lift systems due to extreme flow rates (>100 L/s), elevated temperatures (>125 °C), high motor power requirements (>2,000 HP), and the presence of scale and abrasive solids. This paper presents the design, validation, and field performance of a new GeoESP® pump intake, focusing on geometry optimization, flow dynamics, and mechanical reliability validated through simulation and field deployment. The study combined iterative mechanical design, computational fluid dynamics (CFD), and field testing. Various intake geometries were evaluated across flow conditions to assess pressure losses, velocity distribution, and erosion risk. Key refinements included perforation layout, intake length, and bearing configuration. The optimized design was deployed in high-flow geothermal wells, with SCADA data—such as flow rate, intake pressure, power consumption, and run life—used to benchmark performance against legacy systems. CFD results showed improved inlet hydraulics, including a more uniform velocity profile and approximately 50% reduction in pressure drop. Lower wall shear stress indicated reduced erosion potential. Field deployments confirmed these findings, demonstrating stable operation without plugging, shaft failure, or abnormal vibration, even in scaling environments. Systems achieved reduced power consumption and improved thermal behavior, with run life extended by over 20% in some cases while sustaining flows up to 185 L/s. This paper introduces a novel intake design that applies advanced flow‑distribution concepts and CFD analysis to geothermal ESP applications. The results confirm that optimized intake geometry and enhanced bearing design significantly improve performance and reliability, offering a robust solution for high-flow applications.
| ||
